« Tools · Electrical Calculators

Solar Panel Calculator

Enter your monthly consumption to see the number of panels, installed power, yearly production and approximate area required.

Calculations run in your browser; the data you enter is never sent to any server.

Get a quote for solar PV design, power factor correction and electrical contracting for your facility; engineering consultancy is also available.

Get a Quote »
Results are for preliminary design and checking only. Final design must follow the applicable standards, the manufacturer's catalogue and approval by a qualified engineer; ZDK Mühendislik accepts no liability for how results are used.

How to use

  1. Enter your average monthly electricity use (kWh) from your bill.
  2. Set the average daily peak sun hours for your region and the system efficiency.
  3. Enter panel power and area; panel count, installed power and production appear.

Method and assumptions

  • Required power (kWp) = daily consumption / (peak sun hours × system efficiency). The panel count is rounded up.
  • Peak sun hours (PSH) are the daily irradiation expressed as hours at 1 kW/m²; in Turkey the yearly average is roughly 3.5–5.5 hours depending on region (lower in the north, higher in the south). The default 4.5 is a typical middle value.
  • System efficiency (about 75–85 %) covers inverter, cable, temperature and soiling losses. Area is the sum of panel areas; row spacing and shading must be assessed separately. Seasonal variation, storage and net metering are not included.

Worked example

Monthly use 350 kWh, peak sun hours 4.5, system efficiency 80%, panel rating 550 W, panel area 2.6 m².

Daily use = 350 / 30 = 11.67 kWh. Required power = 11.67 / (4.5 · 0.80) = 3.24 kWp. Number of panels = 3,240 / 550 = 5.9 → 6 panels (3.3 kWp). This system produces about 356 kWh a month (102% of use) and about 4,336 kWh a year. The area needed is about 15.6 m².

Required power by peak sun hours (350 kWh/month, 80% efficiency)

Peak sun hoursRequired power (kWp)550 W panels
3.54.178
4.03.657
4.53.246
5.02.926
5.52.655

In Turkey the annual average peak sun hours are about 3.5-5.5 depending on region. For your site use a value from a solar atlas or an engineering calculation.

Common mistakes

  • Confusing panel rating with output: a 550 W panel yields about 2-2.5 kWh a day after sun hours; peak power is not produced every hour.
  • Ignoring shading: a chimney, tree or neighbouring building lowers output noticeably.
  • Skipping orientation and tilt: a south-facing surface tilted close to the latitude is most productive; east-west and flat roofs behave differently.
  • Ignoring the use profile: production is in the daytime, use may be in the evening; storage or net-metering rules change the result.
  • Treating the result as a final design: this is a preliminary sizing; roof capacity, inverters, cables and grid-connection permits need their own design.

Frequently asked questions

How many panels for 350 kWh per month?

With the defaults (4.5 hours, 80 % efficiency, 550 W panels) about 6 panels, i.e. 3.3 kWp.

Where do I find peak sun hours?

Divide your region's yearly irradiation (kWh/m²·year) by 365; see sources such as an official solar potential atlas.

Can I install a system from this result?

No; this is preliminary sizing. Roof orientation and tilt, shading, inverter selection and regulations need a survey and design.

How many panels for 350 kWh a month?

With the default values (4.5 hours, 80% efficiency, 550 W panels) you need 6 panels, about 3.3 kWp.

How do I find my monthly use?

Look at the kWh values on your electricity bill; if use varies by season, divide the annual total by 12.

Can I build a system from this result?

No. The result gives a first idea; roof, shading, inverter, protection and grid-connection conditions must be designed by an engineer.

More tools